DIMENSIONS
All dimensions in mm (inches)
REAR
VIEW
ACV ACI COM COM V+ V- LP- LP+
V+
DP1
DP2
DP3
TST
HLD
ALM
XDP
RB
Required F.S.R. RA2 RBRA1
200mV 0R 0R Open
2V 910k 100k
20V 1M 10k
200V 1M 1k
2kV (factory default) 464K 536K 100R
2mA (factory default) - - 100R
20mA - - 10R
200mA - - 1R
2A - - 0.1R
20A - - 0.01R
➀ ➁
➂ ➃
0R
0R
0R
DPM 970 Digital AC Voltmeter Module
19mm (0.75“) Digit Height
Screw Terminal Connections
Digital Hold
500V a.c. (2kV ) Full Scale Reading
Measures Voltage and Current
LED Backlighting
A 3 ½ digit LCD panel meter, featuring 19mm (0.75“) digit height and LED backlighting, the DPM 970 is a true RMS voltage and current meter with 500V a.c.
(2kV ) and 2mA full scale readings as standard. By changing the value of scaling resistors or adding a shunt, this module will measure most a.c. voltages and
currents. The DPM 970 features auto-zero and suppression of d.c. offset voltage. The digital hold function freezes the last displayed reading. Calibration is
achieved via two multi-turn potentiometers for offset and scale. Connection to the meter is via screw terminals. The module is housed in a robust carrier
which can be bolted in place or panel mounted using the bezel, window and clips provided.
* To ensure maximum accuracy, re-calibrate periodically.
** Maximum safe input voltage across the ACV and COM terminals is 500V .
RMS
RMS
If voltages to be measured exceed 500V , then fit scaling resistors
externally to the module.
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 0.5 1.5 % (±2 count)
Sample rate 3 samples/sec
Operating temperature range 0 50 °C
Temperature s 200 ppm/°C
Frequency range (input voltage) 15 15k Hz
Input impedance (2kV range) 1 M
DC Supply voltage 7.5 9 14 V d.c.
Supply current (Backlighting off) 1.5 mA d.c.
Supply current (Backlighting on) 50 mA d.c.
Full scale reading ** 0 1999 V
Resolution 1 V
RMS
RMS
tability
@ 5Vd.c.
Stock Number
Standard Meter DPM 970
61.5 (2.42)
51.0 (2.01)
Ø5.7
(0.22)
24.5 (0.96)
24.0 (0.94)
39.0 (1.54)
Ø3.0
(0.12)
71.5 (2.81)
d
76.0 (2.99)
72.5 (2.85)
40.5 (1.59)
44.0 (1.73)
24.0 (0.94)
51.0 (2.01)
a
b
c
a. 1.0 (0.04)
b. 2.0 (0.08)
c. 6.5 (0.26)
d. 11.5 (0.45)
51 (2.01)
24 (0.94)
Display in Test Mode
WEBSITE: http://www.lascarelectronics.com/
Panel cut-out 72 x 40 (2.83 x 1.57)
Maximum panel thickness 3mm (0.12).
SCALING
The value of the three scaling resistors RA1, RA2 and RB may be
altered in order to change the full scale reading (F.S.R.) of the meter
- see table.
The meter will need re-calibration by adjusting the
CAL potentiometer.
To ensure that the meter reads "000" with zero input
voltage/current, short circuit ACV and COM and adjust the ZERO
potentiometer.
NOTE
Use inputs ACV and COM for measuring voltage.
For measuring voltages above 500V RMS, exter nal scaling
resistors must be used.
Use inputs ACI and COM for measuring current.
We recommend the use of a current transformer when
measuring in excess of 10 Amps. Consult current transformer
manufacturer’s data for connections and recommendations.
Other scaling factors can be achieved via the correct selection of
RA1, RA2 and RB values.
CAL ZERO
RA1
RA2
Page view 0
1 2

Summary of Contents

Page 1 - Digital AC Voltmeter Module

DIMENSIONSAll dimensions in mm (inches)REARVIEWACV ACI COM COM V+ V- LP- LP+V+DP1DP2DP3TSTHLDALMXDPRBRequired F.S.R. RA2 RBRA1200mV 0R 0R Open2V 910k

Page 2 - SAFETY WARNING

APPLICATIONSWARNING : Do not apply in excess of 500V a.c. to the meter.3-Phase Current and VoltageMeasurementLoadPSU 303Phase 3NeutralV-V-V+110/240V+5